Time-out, Recording (only when the n-8000af is used), Recording – Toa N-8000 Series User Manual

Page 289: Only when the n-8000af is used), P. 2-178

Advertising
background image

2-178

Chapter 2

FUNCTIONS AND OPERATION

OTHER FUNCTIONS (CONVENIENT FUNCTIONS)

2. TIME-OUT

This function restricts the duration of calling, conversation, and paging to prevent the speech path from being

left unused when a user neglects to terminate conversation or paging.

When the set time has elapsed, stations automatically return to standby state.

Notes

• Use the supplied N-8000 Setting Software to set each time limit (programmable for 10 − 990 seconds in

10-second units). (Refer to

p. 5-36

,

5-43

,

5-54

,

5-63

,

5-90

,

5-98

.)

• Call time limit is not applicable to Emergency calls.

• Conversation time limit is not applicable to Emergency conversations.

• Paging time limit is not applicable to Emergency paging.

Tip

The time limit is programmed at the exchange to which the station that makes the call is connected, or at the

IP station that makes the call.

3. RECORDING

(only when the N-8000AF is used)

The audio signals when the master station or telephone is engaged in the following operations can be recorded.

Master station: conversations, conference calls, paging, and scan monitoring

Telephone:

conversations, paging, and scan monitoring

Recording starts as soon as the operation above is performed at the master station or the telephone set to

enable recording function. Recording ends when such operations end.

It is also possible to record conversations of the outside line telephones. Such conversations and conferences

are recorded on recorders connected to the N-8000AF.

Contact 1 (fixed) closes during recording.

Notes

• The N-8000AF Audio Interface's operating mode must be set to "Conversation Recording."

• Use of the recording function and the N-8000AF Interface to be used for recording must be preprogrammed

into each Master Station and telephone.

• Use the N-8000 Setting Software to set the N-8000AF Interface unit's operation mode, and the use of the

recording function of the individual Master Stations and telephones. (Refer to

p. 5-66

,

p. 5-81

,

p. 5-89

,

p.

5-100

,

p. 5-106

.)

• Master Stations connected to the N-8010EX Exchange cannot use the recording function.

• Up to two Master Stations connected to the N-8000EX Exchange can be set to use the recording function.