Toa N-8000 Series User Manual

Page 369

Advertising
background image

3-65

Chapter 3

INSTALLATION & WIRING

RS-480

Handset cables

Handset cables

Wall surface

RS-481

RS-480 (top)

Note

When using the RS-481 Option handset, cut the

jumper wire next to the handset joint connector on

the circuit board as illustrated at right.

If not cut, sound comes out from the RS-480's front

speaker and returns back to the handset’s

microphone, resulting in acoustic feedback.

Jumper wire

Handset joint

connector

13.6.2. RS-480 and external relay connections

External

power supply

Relay

Diode

24 V DC

GND

+

Blue (HOT)

White (COM)

Open collector output: 24 V DC, Max. 30 mA

RS-480

13.6.3. RS-480 and RS-481 connections

Connect the RS-480 handset cables to the RS-481's handset connection cables.

Note: Cut out the control cables if they are not used to avoid short-circuiting.