SYSTEM SETTINGS BY SOFTWARE

Station: Function Settings

5-81

(8) Calling station indication/CCTV control

Control output :

Set the Multi interface unit's, Direct select unit's, or Audio interface unit’s unit number

and contact output terminal number, which provide a make signal when the station is

called.

Called station's No.: Provides a make contact when the station to be set here is called. Up to 8 stations can

be set.

When the C/O interface unit is set as a called station, enter "#", followed by the

access number. For example, when setting the C/O interface unit with access number

"05," enter "#05".

(Example)

The operation example illustrated below is based on the following settings:

Station No.: 101

Control Output

MI Equipment No.: 5

Contact output No.: 3

Called station's No.: 105

Call

No.101

No.105

1

0

5

N-8000MI (Equipment No. 5)

Contact Output No. 3

Make contact

The Multi interface unit's (equipment No. 5) Contact No. 3 closes when the station No. 101 calls the station

No. 105.

(9) Record conversation

Records Station conversations.

The conversation of the station is provided from the audio output of the designated N-8000AF audio

interface unit.

(10) User Access Code (Master station only)

Sets whether or not to enable the Access code authentication.

Enter the access code number (4-digit number).

(11) Audio Trigger (Door station only)

Performs the audio trigger settings for the station.

Access to audio trigger: Set whether or not to use the audio trigger function.

(12) Mode (Door station only)

Selects operation when audio is detected.

Call master:

Calls the master station.

Monitor:

The station’s audio is output from the master station’s handsfree speaker.

Remote contact:

Provides a one-shot pulse to close the contact output of the designated device.