P. 5-117 – Toa N-8000 Series User Manual

Page 527

Advertising
background image

Chapter 5

SYSTEM SETTINGS BY SOFTWARE

Direct Select: Contact Output

5-117

5.12.4. Contact output setting

Step 1. Click "Contact Output" tab to display the following setting screen.

Step 2. Set each item of "Contact output."

Set the access number for the contact output terminal to be activated when the station performs

external equipment control (one-shot make output or make/break output).

(1) Contact output No. (Can't be edited.)

The Direct select unit's contact output terminal number.

(2) Access No. digits

Select the number of digits to be used when controlling external equipment at the station.

(3) Access No.

Set the access number of the digit set in "Access No. digit", which is used to control external equipment at

the station.

Notes

• The access number cannot be set to "0."

• If the number of digits of the access number is 4, the usable numbers range from "0001" to "6144."

(4) Device

Enable or disable relay and LED outputs.

(5) line status

Select the line to be diagnosed.

The specified contact output terminal is closed when such status is judged abnormal that the CPU failure is

detected on the line or the line is not connected though the station number has been registered.

(6) Network status

Select the equipment to be diagnosed.

The specified contact output terminal is closed when the equipment is judged failed if no response is

detected from it.

Advertising