P. 3-58 – Toa N-8000 Series User Manual

Page 362

Advertising
background image

3-58

Chapter 3

INSTALLATION & WIRING

Protection cover fixing screw
(the screw removed in

Step 1)

Rubber bushing
(supplied with the N-8020MS)

Protection cover

Since wire leads can be pinched,
make them as short as possible.

Step 4. After inserting the cables in the supplied rubber bushing, insert the bushing into the station, then put

the protection cover back in place.

N-8031MS rear

Handset connection terminal

RS-191 rear

Handset jumper

Socket

N-8031MS

Handset cable

Handset cable

Ferrite clamp

(supplied with the N-8031MS)

Handset connection terminal

RS-191

13.2.4. N-8031MS and RS-191 connections

Connecting the RS-191 Option Handset to the N-8031MS permits handset conversation.

Step 1. Remove the handset jumper attached to the N-8031MS's handset connection terminal, then insert it to

the socket on the RS-191's rear PC board.

Step 2. Install the ferrite clamp (supplied with the N-8031MS) onto the RS-191's handset cables. Then, connect

the cables to the N-8031MS's handset connection terminal.

Note

Though the socket on the PC board is faced inside, you can

insert the handset jumper into the socket from the side.

Note

Run the cables along the ferrite groove,

and clamp them.