Paging busy input (only when the n-8000mi is used), Contact bridge function, Only when the n-8000mi – Toa N-8000 Series User Manual

Page 300: 8000di/8050ds/8540ds/8640ds/8650ds is used), Paging busy input, Only when the n-8000mi is used), P. 2-189

Advertising
background image

2-189

Chapter 2

FUNCTIONS AND OPERATION

OTHER FUNCTIONS (CONVENIENT FUNCTIONS)

N-8000MI/8000DI

N-8640DS

N-8000MI/8000DI

LAN

Contact input

Contact output

N-8050DS

Contact output

N-8000EX/8010EX

Contact output

15. CONTACT BRIDGE FUNCTION

(only when the N-8000MI/8000DI/8050DS/8540DS/8640DS/8650DS is used)

Contact signals can be transmitted by way of a network.

[Input interlock level]

ON

Input

OFF

ON

Output

OFF

[Input interlock edge]

ON

Input

OFF

ON

Output

OFF

50 ms

50 ms

50 ms

50 ms

Either of the following 2 control input's operation modes can be selected.

Notes

• The input is defined when its level remains constant for 50 ms after change.

• Use the supplied N-8000 Setting Software to make settings for the contact bridge function. (Refer to

p. 5-48

,

5-116

.)

• Contact signals cannot be transmitted to the RS-180/480 Substation or RS-442 Switch board.

16. PAGING BUSY INPUT

(only when the N-8000MI is used)

When the N-8000 system is interlocked with a large PA system such as an airport broadcast system, busy data

from the host system can be received, allowing important broadcast to be paged consistently.

N-8000MI

Busy signal

Audio signal

Large airport broadcast

system, etc.

Note

Use the supplied N-8000 Setting Software to set the contacts to be used for paging busy input. (Refer to

p.

5-49

.)