P. 5-107 – Toa N-8000 Series User Manual

Page 517

Advertising
background image

Chapter 5

SYSTEM SETTINGS BY SOFTWARE

Audio Interface: Function Settings

5-107

(3) paging

Set the operation mode of the audio interface unit.

Delay Time:

Set the delay time before paging is initiated.

Aux input paging priority:

Allows external input broadcasts to take precedence over all-zone paging

and individual zone paging.

(4) Input level

Set the audio input sensitivity.

(5) Time sync function

Set the Time sync function.

Adjust enable:

Set whether or not to enable the time sync function.

Start time/End time:

Set time ranges that make the time sync function operable.

Note

This function cannot be used simultaneously with the NTP Client function.

(6) Time signal

This function sets the schedule for the time signal.

Clicking the "Schedule settings" button displays the schedule setting screen.

Step 3. Set the schedule.

(1) Signal activation time

Set the activation time interval for individual sound sources (1 – 1,024 sec).

Sound source numbers 1 – 5 correspond to an internal sound source, while numbers 6 – 9 correspond to

an external sound source (contact outputs 1 – 4).