P. 5-43 – Toa N-8000 Series User Manual

Page 453

Advertising
background image

Chapter 5

SYSTEM SETTINGS BY SOFTWARE

Multi Interface: Function Settings

5-43

5.5.3. Function settings

Step 1. Click "Function Settings" tab to display the following setting screen.

Step 2. Set individual items.

(1) Oneshot make time (second)

Sets the duration that the external control output terminals are shorted momentarily.

The setting range is from 1 to 9 (in 1-second units).

(2) Time limit

Set the time-out value for calling, conversation or paging functions in ten-second units between 10 and 990

seconds.

Call time-out:

Set whether to limit the duration of a call to the station. If setting a timeout, enter

the time limit after which calls to the station are automatically terminated. If not

setting a timeout, calls will continue until they are cancelled or the called station

responds.

Conversation time-out: Set whether to limit the duration of conversations with the station. If setting a timeout,

enter the time limit after which conversations to the station are automatically

terminated. If not setting a timeout, conversations will continue until executing the

termination operation.

Paging time-out:

Set whether to limit the duration of paging call with the station. If setting a timeout,

enter the time limit after which paging calls to the station are automatically

terminated.

If not setting a timeout, paging calls will continue until executing the termination

operation.

Advertising