background image

2-154

Chapter 2

FUNCTIONS AND OPERATION

N-8000AL TELEPHONE INTERFACE CONNECTED TELEPHONE

N-8640DS/8650DS

: Designation number for the contact output

Contact output 1 0
Contact output 2 1
Contact output 3 2
Contact output 4 3
Contact output 5 4

Door lock

control

X

Hook-flash

X

Contact output

[Operation (when using the contact outputs of the N-8640DS/8650DS)]

The N-8640DS/8650DS has 5 contact outputs. The contact output to be controlled can be selected through

key operation.

Step 1. Hook-flash* during a two-party conversation.

The current conversation is placed on hold, transmitting a hold tone to the other party.
* Momentarily depressing the receiver switch.

Step 2. Press the [ ] key, followed by the designation number (0 − 4) for the contact output of the IP door

station to be controlled.

Designation number for the contact output 1 (open collector) : 0

Designation number for the contact output 2 (open collector) : 1

Designation number for the contact output 3 (open collector) : 2

Designation number for the contact output 4 (open collector) : 3

Designation number for the contact output 5 (relay) :

4

Contact outputs of N-8640DS/8650DS in conversation can be shorted for a set period of time.

For example, the corresponding door lock can be released if contact outputs are connected to an

electronic lock system.

Step 3. A confirmation tone sounds, and the original conversation is restored.