P. 5-73 – Toa N-8000 Series User Manual

Page 483

Advertising
background image

Chapter 5

SYSTEM SETTINGS BY SOFTWARE

IP Station: Remote Mic Settings

5-73

Step 4. Perform priority setting.(N-8600MS and N-8610RM)

Select one of 2 settings in the table below when making simultaneous paging/zone broadcasts.

Options

Settings

N-8000

Paging with call tone, delay time, and time-out set in the Function setting (see

p. 5-63

)

SX-2000 Chime tone,delay time, and time-out set in the Remote microphone setting (see

p. 5-72

)

Step 5. Perform Function key setting. (Subsequent settings: N-8610RM)

Note: Two kinds of functions can be assigned to each Function key; one is the function that works

when the function assigned Function key is pressed and the other is the function that works

when both the Function key and Shift key are simultaneously pressed.

5-1. Set the number of the RM-210 Remote Microphone Extension units.

Select the number of the units.

The setting range is from 0 to 4.

5-2. Set the function to be assigned to the Function key.

Select the line of the key to be set, then select the desired function from the pull-down menu on the

"Key+Shift" tab.

Function key's names are as follows.

The following functions can be set.

"Zone(SX)," "Tenkey," "Function," "General Broadcast (SX)," "BGM (SX)," "Control Output (SX),"

"Onetouch Dial," or "Station no. (N-8000)."

Click on the line of the Function key to be set, then select the function from the pull-down menu on the

right side of the screen.

5-3. Set the details of the function to be assigned to the

Function key.

Read the next page regarding the detailed settings for

each function.

5-4. Assign another different function to the Function key as

needed.

If the "Key+Shift" tab is selected, another function of

"Volume +," "Volume −," "Mic indicator," or "Privacy (N-

8000)" can be assigned to the Function key.

When the Function key is pressed while holding down

the Shift key, the 2nd function assigned to it on the "Key

+ Shift" tab works.

N-8610RM

1

EMG

SYS1

SYS2

SYS3

10

N-8610RM top panel

Function key

Function key

11

20

21

30

31

40

41

50

RM-210 top panel

Function key

(1st unit) (2nd unit)(3rd unit)(4th unit)

Advertising