13.15. Connector Connection

13.15.1. Mini-clamp connector connection

Connect the mini-clamp connector supplied with the N-8000EX, N-8010EX, N-8000MI, N-8000CO, N-8000AL

to a cable using a commercially available tool (pliers).

Step 1. Cut off two-cable ends in equal length, and insert them

securely to a cover section (transparent side) of the

mini-clamp connector.
Note

Insert the cable without stripping the cable jacket.

For cables, refer to

p. 3-81

, "Type of Cable."

Step 2. With a pair of pliers, lightly pinch the mini-clamp cover

and, after ensuring that the cable is securely inserted,

firmly squeeze on the cover.
Note

Squeeze on the mini-clamp cover until it is correctly

locked.

Cover (transparent side)

Cable

Mini-clamp connector

(supplied with the

N-8000EX/8010EX/8000MI

8000CO/8000AL model

232D-02S1B-DA5

manufactured by DDK Ltd.)

Step 3. Insert the wired connector (plug) into the exchange's connector (socket) until it locks into place.

Rear panel

Note: This figure shows the N-8000EX.

For cables, refer to

p. 3-81

, Type of Cable.

Note

Do not solder on exposed inner cables when using a stranded

wire.

13.15.2. Terminal plug connection

Step 1. Strip a cable jacket of approx. 7 mm (approx. 5 mm for the N-8031MS/8033MS only) from the cable

end.