Symptom

Potential Cause/Place to Inspect

Remedy

No voice is output or the

sound is distorted.

The exchange or any kind of interface

unit may not be connected correctly to

the amplifiers and/or speakers.

Connect the amplifiers and/or

speakers correctly.

The amplifier's audio input volume

control may not be adjusted correctly.

Adjust the audio input volume control

correctly.

The amplifier's audio input level

selector switch may not be set

correctly.

Set the audio input level selector

switch correctly.

Voice and sound settings may not be

performed correctly.

Perform the "Broadcast Specification"

setting correctly. (See

p. 5-33

,

5-41

,

5-53

,

5-61

,

5-88

,

5-96

,

5-105

.)

Microphone's audio level of the

partner station may be extremely low.

Partner's microphone (handset) may

not be connected correctly or opening

of the partner's microphone for hands-

free use may be blocked.

Check to see if the indication "Input

audio error" is displayed in the

operation log of the exchange or

"DSP silent fault" is displayed in the

operation log of the IP station.

Check the contents of log. (See

p.

6-34

.)

Connect the partner's station handset

correctly or remove obstacles that

block the opening of the partner's

station microphone for hands-free use.

Voice signals include

intermittent noise or

break up.

The network may be congested. Check

the contents of log. (See

p. 6-34

.)

When the network is congested,

consult with the network administrator.

No sound is output from

the station speaker.

Station's internal speaker (handset)

may not be connected correctly.

Connect the handset correctly.

No sound is output from

the station's internal or

external speaker.

(N-8000MS/8020MS/

8500MS/8600MS only).

The speaker selector switch may not

be set correctly.

Set the speaker selector switch

located on the station's bottom surface

to the speaker type you want to use.

The exchange generates

excessive heat.

Check to see if the exchange's front

panel-mounted Status indicator flashes

continuously.

The exchange may be malfunctioning.

Contact your nearest TOA sales office

immediately.

The system temporarily

stops operating but is

restored after a few

seconds.

Check to see if the indication

"Firmware failed. Please contact

our sales office." is displayed in the

operation log.

A problem has occurred and the

system has been reset. Nonetheless,

since there is a chance that the system

may fail again, please contact your

nearest TOA sales office immediately.