17. SYSTEM DIAGNOSIS

(only when the N-8000MI/8000DI/8000AF is used)

The N-8000MI/8000DI/8000AF diagnoses the system condition, and provides its results at the contact output

terminal as open or closed contact. The system diagnosis is performed in a way that the N-8000MI/8000DI/8000AF

connects the target equipment via the network.

The contact output terminal is closed only when an abnormality has been detected.

Thereafter, its closed terminal opens when the N-8000MI/8000DI/8000AF judges the condition to be normal.

This function aims to diagnose the exchange's line status and the network status of the connected equipment.

Use the N-8000 Setting Software to perform settings for the network lines and equipment to diagnose. (Refer

to

p. 5-49

,

5-110, 5-117

.)

Note

Diagnosis is performed at the set time intervals*. Therefore, the diagnosis results are not obtained in real time.

The system condition, even if a change occurs, cannot be detected in the intervals from a diagnosis to the next

diagnosis.

* Diagnosis results are renewed every 20 seconds or less.

17.1. Line status diagnosis

If the N-8000EX or N-8010EX exchange's line to be diagnosed shows the status below, the N-8000MI/8000DI

/8000AF judges the line to be abnormal.

• Station's CPU failure

• Line synchronization error

• Station number registered but not connected

17.2. Network status diagnosis

The N-8000MI/8000DI/8000AF attempts to communicate with the network-connected equipment to be

diagnosed such as exchange, various kinds of interface unit, or IP station. If no response is detected, the

N-8000MI/8000DI/8000AF judges such equipment to be failed.

[Example]

Diagnosis results can be displayed on a status indicator.