Paging time-out:

Set whether to limit the duration of paging call with the station. If setting a time-

out, enter the time limit after which paging calls to the station are automatically

terminated.

If not setting a time-out, paging calls will continue until executing the termination

operation.

(3) paging with call tone (N-8400RS only)

Sounds a pre-announcement tone when paging is initiated.

(4) Delay Time

Set the delay time before paging is initiated.

(5) paging response mode (N-8400RS only)

Select either “Zone Selection” or “Automatic response” modes when responding to the paging.

Zone Selection:

Responds to a paging call by designating the number of the paging zone. Respond

to the paging party who made the paging to the designated zone last is called. Use

this mode if paging announcements are heard from multiple zones.

Automatic response: Use only the paging response key to make a response. The responding station

is connected to the station that made a paging call over the paging zone through

which the responding station last received a call.

(6) Calling station indication

Select either “During call and talk” or “During talk” mode when performing the calling station indication

function.

The table below shows the timing that the Multi interface unit’s, Direct select unit’s, or Audio interface unit’s

contact output is closed.

(N-8400RS only)

Calling station indication

Station operation

Calling

Being called

Call waiting

Talking

Being paged

Receiving scan monitor

During call and talk

During talk

Open

Open

Open

Closed

Open

Closed

Closed

Closed

Closed

Closed

Open

Closed

Advertising