Toa N-8000 Series User Manual

Page 184

Advertising
background image

2-73

Chapter 2

FUNCTIONS AND OPERATION

MASTER STATION'S FUNCTIONS AND OPERATION

[Door station one-shot make output operation (when the N-8640DS/8650DS is used)]
The N-8640DS/8650DS has 5 contact outputs. Function designation number differs depending on the contact

output to be controlled.

Press the function designation number corresponding to the contact output, followed by the door station number

to be controlled.

3

3

X

X

......

3

4

X

X

......

3

5

X

X

......

3

6

X

X

......

3

7

X

X

......

Door station No. (2 – 6 digits)

Function designation number

To control the contact output 1

To control the contact output 2

To control the contact output 3

To control the contact output 4

To control the contact output 5