13.7. Multi Interface Unit Connection

1. Power supply connection

Connect the supplied power supply cord to AC

Mains or a UPS (Uninterruptible power supply).

About power supply cord handling

The supplied power supply cord is designed for

exclusive use with the N-8000MI.

Never use it with other equipment.

2. Contact input terminal connection

(Refer to

p. 3-83

, Terminal plug connection.)

[Specification of no-voltage make contact input]

Short-circuit current: 10 mA

Open-circuit voltage: 12 V

3. Contact output terminal connection

Contact output terminals have no polarity.

(Refer to

p. 3-83

, Terminal plug connection.)

[Specification of relay contact output]

Withstand voltage: 24 V DC

Control current: Max. 0.5 A

* Select an appropriate UPS taking into consideration the total power consumption of all system components

and the required backup time. On-line uninterruptible power supply (UPS) is recommended.
Reference

Multi interface unit: 19 W (rated) for CE version, 16 W (rated) for CU version

8-Port 10M/100M Switching Hub: 10W (Differs depending on products.)

[General description of connection]
For cables, refer to

p. 3-81

.

Be sure to ground this

terminal unless the unit

connects to a PBX.

(For grounding in PBX

connection, refer to

p. 3-61

.)

9P removable terminal plug

(supplied with the N-8000MI)

N-8000MI

Contact input signals

Contact output signals

Contact input signals

Contact output signals

To AC mains or a UPS

(Uninterruptible power supply system)*
Note
If there is a danger of lightning strikes,

insert an appropriate surge arrester

into the power line.

Be sure to ground this

terminal unless the unit

connects to PBX.

(For grounding in PBX

connection, refer to

p.

3-68

.)