Interface unit – Toa N-8000 Series User Manual

Page 77

Advertising
background image

1-60

Chapter 1

GENERAL DESCRIPTION

6.4. Interface unit

6.4.1. N-8000MI Multi Interface Unit

[Front]

1 2 3 4 5

[Rear]

1. Reset key [RESET]

Pressing this key reactivates this unit.

2. LNK/ACT indicator [LNK/ACT] (green)

Lights when connected to a network, and flashes

while transmitting or receiving data.

3. Status indicator [STATUS] (red)

Continuously lights while data is written to an

internal storage medium (FlashMemory).

Flashes if there is a failure. (Refer to

p. 8-14

.)

4. Power indicator [POWER] (green)

Lights when power is supplied to the unit.

5. mAC address

This is the MAC address

*1

for the unit. Since the

relationship of each unit location to its MAC address

is established when setting the network attributes,

keep track of this relationship for later use.

*

1

The inherent address assigned to each network

component, expressed in 12-digit hexadecimal

notation.

M

E

M

E

6

7

8

9

10 11

12

13

14

15

6. Functional earth terminal [SIGNAL GND]

Be sure to ground this terminal unless the unit

connects to a PBX.

Note: This terminal is not for protective earth.

7. AC inlet

Connect the supplied power cord.

Note

If there is a danger of lightning strikes, insert an

appropriate surge arrester into the power line.

8. Cord clamp

Pass the power cord through this clamp to ensure

that the plug does not pull out when the unit is

mounted to a wall. (Refer to

p. 3-10

.)

9. Contact input terminals [CONTACT IN]

No-voltage make contact inputs.

Short-circuit current: 10 mA, Open-circuit voltage:

12 V

Connect using a removable terminal plug.

(Refer to

p. 3-83

, "Terminal plug connection.")

10. Contact output terminals [CONTACT OUT]

Relay contact outputs.

Withstand voltage: 24 V DC, Control current:

Maximum 0.5 A

Connect using a removable terminal plug.

(Refer to

p. 3-83

, "Terminal plug connection.")

11. Input volume controls

[EXTERNAL SIGNAL 1, 2]

Use these controls to adjust the audio input

levels for channels 1 and 2 according to the input

sources.

12. Audio input terminal [AuDIO IN]

Includes audio inputs (maximum 0 dB

*2

, over 10

kΩ, balanced) and contact inputs (no-voltage

make contact, short-circuit current: 10 mA, open-

circuit voltage: 12 V).

Connect using a removable terminal plug.

(Refer to

p. 3-83

, "Terminal plug connection.")

Advertising