Toa N-8000 Series User Manual

Page 380

Advertising
background image

3-76

Chapter 3

INSTALLATION & WIRING

LAN

CONTACT IN

C H

N-8510MS rear

To network

To AC mains

To external control equipment

such as a switch or sensor

1

2

3

Cable

Ferrite clamp

(supplied with the N-8510MS)

13.12.2. N-8510MS connection

1. AC adapter terminal connection

Connect the AC adapter*.

Install the supplied ferrite clamp on the AC adapter

cable by winding the cable around the ferrite clamp

once.

* Use the AC adapter AD-1210P/1215P (optional) or

the equivalent.

As for the usable adapter, consult your TOA

dealer.

2. Message start terminal connection

3. Network connection terminal connection

Can be connected to a network of 10BASE-

T/100BASE-TX in auto-sensing.

Connecting the station to a PoE (Power over

Ethernet) switching hub compliant with IEEE802.3af

eliminates the need for an AC adapter. (For

connection, refer to the instruction manual supplied

with the switching hub.)

Use a straight through cable of UTP category 5 or

more for this connection.

11 mm

COM

HOT

Press down the desired push-

in terminal button with a tip of

standard driver, and insert the

cable securely.

For the type of cables, refer

to

p. 3-73

, Type of Cable.

For the type of cables, refer

to

p. 3-81

, Type of Cables.