2.1. Using the Emergency Call Button

The RS-144 is equipped with a dedicated Emergency Call button.

The call buttons on other substations are also made to have the same function as the Emergency Call button

by changing the priority order settings in advance.

Note

It is also possible to set the RS-144's Emergency Call button not to initiate the emergency calls by changing the

priority order settings.

Step 1. Press the Emergency Call button or lift the handset*.

* When the RS-144 and RS-141 are used in combination
If a Master Station is called, the Emergency Call tone is sounded.

If a Multi-Functional Master Station is called, the Emergency Call

indication is displayed and the Emergency Call tone sounded.

Note

Call time limits are not applicable to the Emergency Call.

Step 2. Begin the conversation if the called station responds. (Emergency

Conversation)

Note

Call time limits are not applicable to the Emergency Conversation.

Conversation is terminated if the called party replaces the handset

or presses the Clear key.

Note

The substations cannot terminate conversations except when handset conversations are made using

the RS-140/142/143/144 in combination with the RS-141 or using the RS-442/480 in combination with

the RS-481.

Notes

• Preprogram the master station or the telephone to call to.

Programming can be performed by dialing operation of the multifunctional master station (refer to

p. 7-10

) or

using the supplied N-8000 Setting Software (refer to

p. 5-56

).

• Use the N-8000 Setting Software to set the call priority order. (Refer to

p. 5-56

.)

2. MAKING AN EMERGENCY CALL

(only when system response mode is set for "Selective Response")

Emergency Calls take precedence over other calls. If the Master Station or telephone responds to the Emergency

Call, the conversation becomes an Emergency Conversation and is handled with a higher priority than other

conversations and paging calls.

Notes

• Only Substations that are set to be capable of making an Emergency Call when the system response mode

is set to "Selective Response" can initiate the Emergency call.

• In the case of the N-8010RS, if the Master Station or telephone responds to an Emergency Call when all

speech links are occupied, a lower-priority conversation, paging call, or scan monitor will be interrupted for

the Emergency Conversation to begin.

• Substations must first be set to allow Emergency Call.

• Use the N-8000 Setting Software to enable or disable Emergency Call operation for the Substation.

(Refer to

p. 5-57

.)

• Use the N-8000 Setting Software to set the system's response mode. (Refer to