Installation of door stations, Flush mounting – Toa N-8000 Series User Manual

Page 342

Advertising
background image

3-38

Chapter 3

INSTALLATION & WIRING

N-8050DS only

Acoustic material (

supplied with the N-8050DS

)

Note

Lay it down along the inside of the box.

Waterproof washer

(supplied with the N-8640DS)

Machine screw

M4 x 25 (supplied with the N-8050DS/8540DS)

or M4 x 20 (supplied with the N-8640DS)

YC-150 Back box

or 3-gang electrical box

N-8050DS/8540DS/8640DS

(This figure represents the N-8050DS/8540DS.)

N-8640DS only

Wall surface

9. INSTALLATION Of DOOR STATIONS

Door station N-8050DS/8540DS/8640DS/8650DS can be installed in either of two ways: (1) flush mounting or

(2) wall surface mounting.

Note

When using the PA paging function, keep the station as far away from the PA paging speaker as possible to

avoid acoustic feedback.

9.1. flush Mounting

[N-8050DS/8540DS/8640DS]

Attach the N-8050DS/8540DS/8640DS to the YC-150 Back box or an electrical box installed in a wall.

Note

The wall should be over 12 mm thick, and the opening in the wall for

an electrical box should be under 115 mm (wide) by 162 mm (high).

• The N-8050DS/8540DS comes with 2 types of screws: M4 x 25

and UNC No. 6-32 x 18.

For the electrical box provided with unified threads, use the UNC

No. 6-32 x 18.

• The N-8640DS comes with 2 types of screws: M4 x 20 and UNC

No. 6-32 x 20.

For the electrical box provided with unified threads, use the UNC

No. 6-32 x 20.

Accessory screws

16

2

92

35

83.5

115

[Installation completion drawing]

Unit: mm

Note

This figure represents the

N-8050DS/8540DS. Dimensions of

the N-8640DS are the same as the

N-8050DS/8540DS.