P. 5-80 – Toa N-8000 Series User Manual

Page 490

Advertising
background image

Chapter 5

SYSTEM SETTINGS BY SOFTWARE

Station: Function Settings

5-80

Step 2. Set individual items.

(1) Incoming call mode

Call receiving mode (

p. 2-10

) can be selected either "Automatic Connection" or "Continuous Call". Call with

a call tone or without a call tone can be set on both modes.

The door station is fixed to "Automatic connection" mode.

(2) level (except the analog master station)

Microphone sensitivity: Station hands-free microphone sensitivity can be adjusted in three increments

from 1 (minimum) to 3 (maximum). The default sensitivity is Level 2.

Note

The sensitivity for the handset microphone is fixed (not adjustable).

Speaker output:

Station speaker output level can be adjusted in five increments from 1 (minimum)

to 5 (maximum). The default sensitivity is Level 3.

Call volume:

Station call volume can be adjusted in five increments from 1 (minimum) to 5

(maximum). The default sensitivity is Level 3.

(3) Group call (max. 15) (Master station only)

Set a group of up to fifteen stations that will be called simultaneously when the station being set now is

called. With this setting, even when a called station is busy, any registered station in the group can respond.

Note

When the call response mode is set to “Selective Response,” the stations connected to the same N-8010EX

Exchange or the N-8400RS Substation Interface Unit cannot be assigned to the group call member stations.

(4) Calls transferred to (Master station only)

Set the station number to which each transfer is to be directed.

When the C/O interface unit is set as a transfer destination station, enter "#", followed by the access

number. For example, when setting the C/O interface unit with access number "05," enter "#05".

Call forwarding receiving station can be set only when the call forwarding function of the Exchange is

enabled. (Refer to

p. 5-35

)

Note

The station to be called via Multi interface unit cannot be programmed as a transfer destination station.

(5) priority call (Selective response mode, Door station only)

Call priorities can be adjusted in five increments from 1 (minimum) to 5 (maximum).

Level 5 is the same priority as an emergency call.

The default sensitivity is Level 1.

(6) BGM

Set whether the station receives BGM broadcasts. If receiving, place a checkmark and select the BGM

channel number (1 – 8; Channel).

(7) Door remote

Set the Multi interface unit's, Direct select unit's, or Audio interface unit’s unit number and contact output

terminal number to be used for door remote control.