Sub stations – Toa N-8000 Series User Manual

Page 398

Advertising
background image

4-10

Chapter 4

SYSTEM DESIGN FLOW

5.4. Sub Stations

Side TAB

Item

Default

Reference

page

Network settings

IP address *

1, 2

192.168.1.1

SW:

p. 5-50

BR:

p. 6-5

Subnet Mask *

1, 2

255.255.255.0

Default Gateway *

1, 2

0.0.0.0

Web server port number *

1, 2

80

SW:

p. 5-51

BR:

p. 6-5

TCP start port number

5000

p. 5-51

UDP start port number

5006

Multicast port number

6000

NAPT compatible

Incompatible

Network ID

1

p. 5-52

WAN IP address

192.168.1.1

WAN Web server port number

80

WAN TCP start port number

5000

WAN UDP start port number

5006

Broadcast specification

High quality sound

transmission mode

p. 5-53

Communication capacity

2990 kbps

Function settings

Call time-out

No limit

p. 5-54

Conversation time-out

No limit

Paging time-out

No limit

Paging response mode

Zone selection

p. 5-55

Calling station indication

During call and talk

Sub-station-interface

Selection

Call master Call 1

-

p. 5-56

Call master Call 2

-

Call master Call 3

-

Call volume

3

Sub-station Selection Line No.

-

Sub-station Selection Sub-station No.

-

Sub-station Selection Sub-station

name

-

Priority Level (Call 1)

1 (5 for RS-144 only)

p. 5-57

Priority Level (Call 2)

1

Priority Level (Call 3)

1

Microphone sensitivity

2

Speaker output

3

Control output / MI/DI/AF equipment No.

-

Control output / Contact output No.

-

Called station's No.

-

Call Activation - push 3 times

OFF

with call tone

ON

Refusal of priority call operation

OFF

Access to emergency call operation

OFF

• All of the above items can be set on the N-8000 Setting Software.

*

1

Be sure to set this since settings and conversations are performed via a network.

*

2

Settings possible from a browser as well.

Advertising