P. 3-55 – Toa N-8000 Series User Manual
Page 359
![background image](/manuals/714265/359/background.png)
3-55
Chapter 3
INSTALLATION & WIRING
13.2. Connections of Stations Used in conjunction with the exchange
13.2.1. Station and exchange connection
The cables from the N-8000EX Exchange to the Station have no polarity.
[N-8000MS/8010MS/8011MS]
To connect the cables from the N-8000EX Exchange to the Master Station, use the connection cable supplied
with each station and a commercially available RJ-11 modular jack.
Connection cable
(supplied with each station)
RJ-11 modular rosette
(commercially available)
Station
To the exchange via
the Terminal Board
Twisted pair cable
[N-8020MS]
To connect the cables from the N-8000EX Exchange to the Master Station, use the connection cable directly
attached to the station and a commercially available RJ-11 modular jack.
N-8020MS
Connection cable
RJ-11 modular rosette
(commercially available)
To the exchange via
the Terminal Board
Twisted pair cable