13.4. Connections of Stations Used in conjunction with the N-8000RS/8010RS

13.4.1. RS-180 and external relay connections

External

power supply

Relay

Diode

24 V DC

GND

+

Blue (HOT)

White (COM)

Open collector output: 24 V DC, Max. 30 mA

RS-180

13.4.2. Substation interface unit and RS-140 Switch panel connections

Connect the cables from the RS-140 to the N-8000RS/8010RS using the supplied removable terminal plug.

13.4.3. RS-140/142/143/144 and speaker connections

3P removable terminal plug

(supplied with the N-8000RS

/8010RS)

N-8000RS/8010RS Substation interface unit

2-core shielded cable

2-core shielded cable

High-impedance speaker

(Impedance: 600 Ω or more)

RS-140/142/143/144

Brown (A)

Red (B)

Orange (C)
Yellow (C+)

Green (B+)

Blue (A+)

Blue (COM)

Green (HOT)

N.C.

Purple (H)

Brown

Red
Orange

Note: This figure represents

the RS-140.

Note

Cut out the unused Wire (purple)

to avoid short-circuiting.

Note: Cut out the control cables if they are not used to avoid short-circuiting.