P. 5-106 – Toa N-8000 Series User Manual

Page 516

Advertising
background image

Chapter 5

SYSTEM SETTINGS BY SOFTWARE

Audio Interface: Function Settings

5-106

5.11.2. Function settings

Step 1. Click "Function Settings" tab to display the following setting screen.

Step 2. Set individual items.

(1) Oneshot make time (second)

Sets the duration that the external control output terminals are shorted momentarily.

The setting range is from 1 to 9 (in 1-second units).

(2) Operation mode

Set the operation mode of the audio interface unit.

Unused:

This unit is not used.

Aux input paging:

Select this item when connecting the Audio interface unit to playback

components or Remote microphone to make paging calls. Paging calls

can be made to the preprogrammed paging zones when the control input

is activated.

Contact input No./Paging No.: Set the paging zone number to be called when the contact input is closed

for each contact input terminal.

Rec:

Select this function when recording the station conversation by connecting

the audio interface unit to a recorder, etc.

Time signal:

Select this function when playing chime tones or other sound sources at

the fixed time or on the fixed day.

Note

Only a single equipment per system can be set to "Time signal."

"Time signal" item in this operation mode can be selected only for the

equipment for which Time signal has been set on the system settings

screen (refer to

p. 5-26

).

2

3

Advertising