Toa N-8000 Series User Manual

Page 371

Advertising
background image

3-67

Chapter 3

INSTALLATION & WIRING

To the tie-line unit of intercom system

or the PBX's analog E&M interfaces

Mini-clamp connector

232D-02S1B-DA5 (DDK)

(supplied with the N-8000MI)

To network

RJ-45 connector

BGM player, etc.

Control output

Control input

Line output *

1

Line input *

1

Amplifier, etc.

*

1

Connect the Line input cables in a way as shown below according to the type

of connected unit's input or output.

N-8000MI

N-8000MI

•

Connecting to a balanced input or output

•

Connecting to an unbalanced input or output

Connected Unit

Connected Unit

Hot (H)

Hot (H)

Cold (C)

Earth (E)

Earth (E)

8P removable

terminal plug

(supplied with

the N-8000MI)

Input volume

controls

N-8000MI

M

E

M

E

Note

You can use only either

of the Audio input/output

CH1 terminals or the PBX

interface CH1 terminal.

Likewise, it is the same for

CH2.

4. Audio input terminal connection

Audio input terminals have no polarity.

(Refer to

p. 3-83

, Terminal plug connection.)

[Specification of audio input]

Max. 0 dB*

2

, over 10 kΩ, balanced

Audio input sensitivity for each channel can be

adjusted in the range of 0 to –25 dB*

2

with the

input volume control. Adjust the input sensitivity

depending on the equipment to be connected.

(Default factory setting: 0 dB*

2

)

[Specification of control input]

No-voltage make contact

Short-circuit current: 10 mA

Open-circuit voltage: 12 V

5. Audio output terminal connection

Audio output terminals have no polarity.

(Refer to

p. 3-83

, Terminal plug connection.)

[Specification of audio output]

Max. 0 dB*

2

, under 600 , balanced

[Specification of control output]

Relay contact output

Withstand voltage: 24 V DC

Control current:

Max. 0.5 A

6. PBx interface terminal connection

Differs depending on the connections to the

Exchange of the EXES-2000 or EXES-6000 by

a tie-line, or to the PBX exchange via the analog

E&M interface.

(Refer to

p. 3-68

for the connection method.)

(Refer to

p. 3-83

, Mini-clamp connector connection.)

7. Network connection

Can be connected to a network of 10BASE-

T/100BASE-TX in auto-sensing.

Use a straight through cable of UTP category 5 or

more for this connection.

*

2

0 dB = 1 V