3-81

Chapter 3

INSTALLATION & WIRING

13.13. Type of Cable

The types of cables are to be determined according to the following conditions.

• To use twisted pair wires (such as those used for electronic push-button telephone) for wiring between the

Exchange and the stations, for wiring between the N-8400RS Substation interface unit and the N-8410MS

Master station or the RS-450/460/470/480 Substations, and for connections to the Multi interface unit's audio

input/output terminals and PBX interface terminals.

• Use a straight through cable of UTP category 5 or more with RJ-45 connector for wiring the equipment to IP

network.

• The number of cables pairs laid should be determined considering the possibility of future expansion of the

system.

• Outdoor wires should be used where wiring passes through inaccessible areas such as ceilings or under

floors where the maintenance is not performed. Indoor wires may also be used, however, in case where there

is no risk of deterioration due to exposure to heat, etc.

• Make sure that the 2-core shielded cable is used for wiring from the N-8000RS/8010RS Substation interface

unit to the RS-150/160/170/180 Substation , RS-140/143/144 Switch panel, or RS-142 Switch board.

Note

Specifications related to each connections are as follows.

Mini-clamp connector (N-8000EX/8010EX line terminal)

(N-8000MI PBX interface terminal)

(N-8000CO C/O line connection terminal.)

(N-8000AL Telephone connection terminal.)

Conductor diameter: ø 0.4 – 0.65 mm (AWG22 – 26), Solid wire

Outside diameter:

ø 1.05 mm or below

Clip terminal (E-7000TB)

Conductor diameter: ø 0.4 – 0.8 mm (AWG20 – 26), Solid wire

Outside diameter:

ø 1.5 mm or below

Removable terminal plug (N-8000EX Paging output terminal.)

(N-8000RS/8010RS/8400RS Line terminal.)

(N-8000MI Control I/O and Audio I/O terminal.)

(N-8000DI Control I/O terminal.)

(N-8000AF Control I/O and Audio I/O and Time sync input terminal.)

Conductor diameter: ø 0.5 – 2 mm (AWG12 – 24), Solid wire/Stranded wire

Removable terminal plug (N-8031MS/8033MS line terminal)

Conductor diameter: ø 0.4 – 1.6 mm (AWG14 – 26), Solid wire/Stranded wire

External speaker terminal (N-8000MS/8500MS/8600MS),

Message start terminal connection (N-8510MS)

Conductor diameter: ø 0.4 – 1.3 mm (AWG16 – 26), Solid wire

ø 0.7 – 1.4 mm (AWG16 – 22), Stranded wire

External speaker terminal, Control output terminal (N-8020MS)

Conductor diameter: ø 0.65 mm (AWG22), Solid wire

ø 0.7 mm (AWG22), Stranded wire

External dial input terminal (N-8031MS/8033MS)

Conductor diameter: ø 0.8 – 1.3 mm (AWG16 – 20), Solid wire/Stranded wire

Station terminal (N-8050DS line terminal, contact output terminal, N-8540DS contact output terminal)

Conductor diameter: ø 0.4 – 1.3 mm (AWG16 – 26), Solid wire/Stranded wire