2-186

Chapter 2

FUNCTIONS AND OPERATION

OTHER FUNCTIONS (CONVENIENT FUNCTIONS)

12. IP DOOR STATION EXTERNAL CONTROL INPUT

(only when the N-8640DS/8650DS is used)

When dialing operations (up to 20 digits) have been preprogrammed into the external control input of the

N-8640DS/8650DS IP Door Station, such dialing operations can be performed by closing the N-8640DS/8650DS's

contact input. Nothing operates even when closing the contact input if no dialing operation is preprogrammed.

The external device make contact signal must be transmitted for at least 100 ms.

Note

Use the N-8000 Setting Software to perform the door station external control input settings.

[Example]

When the dial operation of pressing the call button twice is programmed, closing the N-8640DS/8650DS's

contact input makes the emergency call.

No. 100

Emergency Call to No. 100

N-8640DS/8650DS

Make Contact

Emergency button

Emergency Call tone