Installation of substations, Flush mounting – Toa N-8000 Series User Manual

Page 348

Advertising
background image

3-44

Chapter 3

INSTALLATION & WIRING

Machine screw M4 x 25

(supplied with the substation)

YC-302 or electrical box

Substation

Wall surface

Note: This figure represents the RS-160/170.

[Installation completion drawing]

Accessory screws

Substations come with 2 types of screws: M4 x 25 and UNC No.

6-32 x 18.

For the electrical box provided with unified threads, use the

UNC No. 6-32 x 18.

10. INSTALLATION Of SUBSTATIONS

The Substations can be installed in either of 2 ways: flush mounting using the YC-302 2-gang electrical box or

commercial electrical box, or wall surface mounting using the YC-822/823 Wall-mount box.

Note

When using the PA paging function, keep the station as far away from the PA paging speaker as possible to

avoid acoustic feedback.

10.1. flush Mounting

Mount the substation to the YC-302 or electrical box mounted in the wall.

Note
When installing the RS-170/180/470/480 at outdoor or locations where

it gets wet with water, tightly seal the panel edges. Besides, provide

a weep hole at the underside of the mounting box to permit water to

drain off.

46

120

37

18.2

83.5

120

Unit: mm

Note: This figure represents the RS-160/170.

Seal the panel edges.

Note: This figure represents the RS-480.

Advertising