C/o interface unit connection, Caution – Toa N-8000 Series User Manual

Page 377

Advertising
background image

3-73

Chapter 3

INSTALLATION & WIRING

13.10. C/O Interface Unit Connection

[General description of connection]

For cables, refer to

p. 3-81

.

1. Power supply connection

Connect the supplied power supply cord to AC

Mains or a UPS (Uninterruptible power supply).

About power supply cord handling

The supplied power supply cord is designed for

exclusive use with the N-8000CO.

Never use it with other equipment.

2. C/O line connection

Connect the C/O line to the PSTN (public switched

telephone network) using the supplied mini-clamp

connector.

(Refer to

p. 3-83

, Mini-clamp connector connection.)

3. Network connection

Can be connected to a network of 10BASE-

T/100BASE-TX in auto-sensing.

Use a straight through cable of UTP category 5 or

more for this connection.

N-8000CO C/O interface unit

Be sure to ground.

To AC mains or a UPS

(Uninterruptible power supply system)*

3

Note

If there is a danger of lightning strikes,

insert an appropriate surge arrester

into the power line.

RJ-45 connector

To network

A pair of twisted pair cables

U.S.O.C

*

2

RJ11C or W

Central office line

(or PBX extension)

Mini-clamp connector

232D-02S1B-DA5 (DDK)

(supplied with the N-8000CO)

1

2

3

Protector

*

1

*

1

Install the protector if the telephone

company has not already installed it.

*

2

This terminal is installed by the telephone

company.

Note

The Interface Unit’s DC resistance is 327 Ω

(maximum).

Depending on line resistance conditions, the

unit might not be useable.

*

3

Select an appropriate UPS taking into consideration the total power consumption of all system components

and the required backup time. On-line uninterruptible power supply (UPS) is recommended.
Reference

C/O interface unit: 6 W (rated) for CE version, 6 W (rated) for CU version

8-Port 10M/100M Switching Hub: 10W (Differs depending on products.)

To reduce the risk of fire, use only No.26 AWG or

larger telecommunication line cord.

CAUTION

Advertising