4-19

Chapter 4

SYSTEM DESIGN FLOW

5.9. Audio Interface

Side TAB

Item

Default

Reference

page

Network settings

IP address *

1, 2

192.168.1.1

SW:

p. 5-102

BR:

p. 6-5

Subnet Mask *

1, 2

255.255.255.0

Default Gateway *

1, 2

0.0.0.0

Web server port number *

1, 2

80

SW:

p. 5-103

BR:

p. 6-5

TCP start port number

5000

p. 5-103

UDP start port number

5006

Multicast port number

6000

NAPT compatible

Incompatible

Network ID

1

p. 5-104

WAN IP address

192.168.1.1

WAN Web server port number

80

WAN TCP start port number

5000

WAN UDP start port number

5006

Broadcast specification

High quality sound

transmission mode

p. 5-105

Communication capacity

2990 kbps

Function settings

Oneshot make time

1 second

p. 5-106

Operation mode

Unused

Aux input paging / Paging No.

-

Aux input paging / Paging time-out

OFF

Aux input paging / Time limit

0

Paging Delay Time

0

Aux input paging priority

OFF

Input Level

Line

p. 5-107

Clock adjust / Adjust enable

OFF

Clock adjust / Start time

00:00:00

Clock adjust / End time

00:10:00

Time signal / Schedule settings

-

Schedule Settings

Signal activation time

10

External timer Enable

OFF

Source

1

Paging No.

-

External control Equipment No.

-

p. 5-108

External control Contact No.

-

External control Activation time

10

Name

-

p. 5-109

Time

00:00:00

Day

OFF

• All of the above items can be set on the N-8000 Setting Software.

*

1

Be sure to set this since settings and conversations are performed via a network.

*

2

Settings possible from a browser as well.