2-53

Chapter 2

FUNCTIONS AND OPERATION

MASTER STATION'S FUNCTIONS AND OPERATION

5.3.6. Manually trigger time signal

Time Signal can be activated simultaneously with the master station's dial operation, through which the sound

source number, external equipment control ON/OFF, and paging zone number should be designated.

• The sound source number is designated by "0" to "9."

0: Silent

1: Internal sound source 1 (Trill tone)

2: Internal sound source 2 (Bell 1)

3: Internal sound source 3 (Bell 2)

4: Internal sound source 4 (Chime Tone 1)

5: Internal sound source 5 (Chime Tone 2)

6. External sound source 1 (N-8000AF's Contact Output 1 activated)

7. External sound source 2 (N-8000AF's Contact Output 2 activated)

8. External sound source 3 (N-8000AF's Contact Output 3 activated)

9. External sound source 4 (N-8000AF's Contact Output 4 activated)

• The external equipment control ON/OFF is designated by "0" or "1."

With the external equipment control set to ON, the external equipment preset by the N-8000 Setting Software

can be activated in synchronization with Time Signal Activation.

0: External equipment control OFF

1: External equipment control ON

• When the external equipment control is set to ON, contact output terminals (any of contact outputs 5 − 8,

including those of another N-8000AF, N-8000MI, or N-8000DI) can be closed to operate a bell or other

external equipment in synchronization with Time Signal Activation.

• Up to 10 zones from 192 zones can be selected for paging zones.

Designate them in the zone number digits (1 − 3) preset by the N-8000 Setting Software.

(Example) Zone number when 3-digit number is set: 001, 025, 192

[Operation: Making paging calls to a single zone]

9

+

1

+

X

+

Y

+

Function designation No.

Sound source No.

External equipment control ON/OFF

(confirmation tone)

Z

+

Paging zone No.

Time Signal is activated after the confirmation tone sounds.

[Operation: Making paging calls to 2 or more zones]

9

+

1

+

X

+

Y

+

+

+

Function designation No.

Sound source No.

External equipment control ON/OFF

(confirmation tone)

Z

Z

+

+

Paging zone No.

Max. 10 zones

Paging zone No.

Time Signal is activated after the confirmation tone sounds.