P. 5-67 – Toa N-8000 Series User Manual

Page 477

Advertising
background image

Chapter 5

SYSTEM SETTINGS BY SOFTWARE

IP Station: Function Settings 2

5-67

(12) Audio Trigger (N-8640DS/8650DS only)

Performs the audio trigger settings for the station.

Access to audio trigger: Set whether or not to use the audio trigger function.

(13) Mode (N-8640DS/8650DS only)

Selects operation when audio is detected.

Call master:

Calls the master station.

Monitor:

The station’s audio is output from the master station’s handsfree speaker.

Remote contact: Provides a one-shot pulse to close the contact output of the designated device.

(14) Trigger (N-8640DS/8650DS only)

Selects the trigger.

Level:

Detects sounds of a sound pressure level higher than the set level that last for a specified

period of time.

Audio:

Detects human voices.

Duration (Level): Set the time interval till sounds are detected.

Level:

Set the threshold sound pressure level.

Duration (Audio): Set the duration of the human voice’s vowels to detect.

Sensitivity:

Sets the detection sensitivity of the human voice.

Setting range: 1 – 9 (9 steps, 1: Most likely to detect, 9: Least likely to detect)

(15) External control input (N-8640DS/8650DS only)

Enter the station number to call when the IP door station's contact input is closed.

(16) Door station mode (Sequential response mode, Ip door station only)

Set whether to operate the IP door station in door station mode*.

* The call tone sounds only once at the IP door station when the IP door station calls the pre-programmed

master station. The call timeout and conversation timeout are set to 30 seconds each.

(17) Call Activation - push 3 times (Sequential response mode, N-8640DS/8650DS only):

Sets whether or not to make a call by the operation of pressing the Call button 3 times within 3 seconds.

(18) Access to priority call operation (Sequential response mode, Ip Master station and Ip Remote

microphone station only)

Enables the IP station to initiate priority calls.

This function can only be used when the system has been set for sequential response mode.

(19) Refusal of priority call operation (Sequential response mode only)

Enables the IP station to refuse priority calls from others stations.

(20) Access to emergency call operation (Selective response mode, Ip door station only)

Sets whether or not to allow the IP station to make an emergency call.

This function is only possible for the IP door station when the system has been set for selective response

mode.

(21) Access to paging call operation (Ip Master station and Ip Remote microphone station only)

Enables or disables paging calls from the IP station.

(22) Access to emergency all paging call operation (Ip Master station and Ip Remote microphone

station only)

Enables or disables emergency all paging calls from the IP station.

(23) Access to audio trigger setting operation (Ip Master station and Ip Remote microphone station

only)

Enables or disables audio trigger setting from the IP station.

(24) External equipment control (Ip Master station and Ip Remote microphone station only)

Set whether the one-shot make contact output or make/break contact output is operated at the IP station.

Advertising