8050ds/8540ds/8640ds/8650ds is used), P. 2-71, External equipment control – Toa N-8000 Series User Manual

Page 182: 30 x x

Advertising
background image

2-71

Chapter 2

FUNCTIONS AND OPERATION

MASTER STATION'S FUNCTIONS AND OPERATION

5.8. External Equipment Control

(only when the N-8000MI/8000DI/8000AF/8050DS/8540DS/8640DS/8650DS is used)

External equipment can be controlled by transmitting a one-shot make output signal (or make/break contact

signal) to the contact of the designated Multi-Interface unit, Direct Select unit, or Audio Interface unit, or by

manually causing the station to transmit a one-shot make output signal to the contact of the designated door

station. Remote door lock control can be performed using the one-shot make output, and indication boards can

be controlled using the make/break output.

Note

Use the supplied N-8000 Setting Software to set the one-shot make duration, operation number digits, operation

numbers, and the stations allowed to control external equipment. (Refer to

p. 5-35, 5-43, 5-49 , 5-62, 5-67,

5-82, 5-106, 5-110, 5-114, 5-117

.)

Data receiving device

Door lock control

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

[Door remote control example using one-shot make output control]

[Hospital waiting status indication board example using the make/break output]

3

0

X

X

Contact access No. (2 – 4 digits)

......

Function designation number

[One-shot make output operation]
Press [Function key][3][0], then the access number for the contact corresponding to the external equipment to

be controlled.