P. 5-26 – Toa N-8000 Series User Manual

Page 436

Advertising
background image

Chapter 5

SYSTEM SETTINGS BY SOFTWARE

General: System Settings

5-26

5.3.5. System settings registration

Perform settings common to the entire system.

Step 1. Click "System Settings" tab to display the following setting screen.

(1) Response Mode

Set the Response Mode.

Sequential: Responds to individual calls in order of receipt.

Selective: The master station selects a station and responds to that station.

Note

Selective response mode is invalid in firmware versions earlier than 2.00.

(2) Clock Master Setting

Select the device that functions as the master clock to which all system equipment clocks are referenced.

Only one device per system can be designated as the master clock. If time synchronization has been

enabled in the N-8000AF Audio interface unit, only that N-8000AF unit can be set as the master clock. Also,

the N-8000RS, N-8010RS and N-8400RS Substation interface units cannot be set as the master clocks.

(3) NTp client Setting

Select the device to connect to the NTP server.

Only a clock master-designated N-8000AF can be set as the NTP client within the system.

Note

This function updates only minutes and seconds of the clock of the N-8000AF. Before using this function,

be sure to set the clock master N-8000AF to the correct time. (Refer to

p. 5-128, 6-42

.)

(4) Time Signal Setting

Set the N-8000AF Audio interface unit that uses a time signal.

Advertising