Chapter 5

SYSTEM SETTINGS BY SOFTWARE

C/O Interface: Function Settings 1

5-89

Step 2. Set individual items.

(1) Calling station indication/CCTV control

Control output :

Set the Multi interface unit's, Direct select unit's, or Audio interface unit’s unit number

and contact output terminal number, which provide a make signal when the station is

called.

Called station's No.: Provides a make contact when the station to be set here is called. Up to 8 stations can

be set.

When the C/O interface unit is set as a called station, enter "#", followed by the

access number. For example, when setting the C/O interface unit with access number

"05," enter "#05".

(Example)

The operation example illustrated below is based on the following settings:

C/O interface unit No.: 1

Control Output

MI Equipment No.: 5

Contact output No.: 3

Called station's No.: 105

(2) Record conversation

Records C/O Interface conversations.
The conversation of the C/O Interface is provided from the audio output of the designated N-8000AF audio

interface unit.

(3) Access to paging call operation

Enables or disables paging calls from the C/O Interface.

(4) Access to scan monitor operation

Enables or disables scan monitor from the C/O Interface.

(5) External equipment control

Set whether the one-shot make contact output or make/break contact output is operated at the C/O

Interface.

N-8000MI (Equipment No. 5)

Contact Output No. 3

Make contact

Call

Call

Outside line telephone

No.105

N-8000CO (Equipment No. 1)

1 0 5

X

X

(Dial

confirmation tone)

N-8000CO's

outside line number

The Multi interface unit's (equipment No. 5) Contact No. 3 closes when the C/O interface unit (equipment

No.1) calls the station No. 105.