Basic Operation

6.1.2 Frequency Reference Settings: b1-01, H3-01, H3-08, H3-09

- 6

Signal Level for Multi-function Analog Input, Terminal 16: H3-04

D

Set the signal level for the multi-function analog input.

User

Change

during

Setting

Factory

Valid Access Levels

User

Constant

Number

Name

during

Opera-

tion

Setting

Range

Unit

Factory

Setting

Open Loop

Vector

Flux Vector

H3-04

Signal level selection
(terminal 16)

0 1

--

0

B

B

D

Settings

Setting

Function

0

0 to 10 VDC input [11--bit + polarity (positive/negative) input]

1

--10 to 10 VDC input
(A negative voltage is a reference for reverse rotation.)

J

Adjusting Analog Inputs: H3-02, H3-03, H3-06, H3-07, H3-10, H3-11, H3-12

D

There are three constants used to adjust the analog inputs: The gain, bias (both set separately for each
input), and filter time constant (a single value for all of the inputs).

x

The gain and bias can be adjusted separately for each analog input (terminals 13, 14, and 16).

Gain:

Set the frequency corresponding to a 10 V (20 mA) input as a percentage of the
maximum frequency. (The maximum output frequency set in E1-04 is 100%.)

Bias:

Set the frequency corresponding to a 0 V (4 mA) input as a percentage of the
maximum frequency. (The maximum output frequency set in E1-04 is 100%.)

x

Set the gains and biases for terminals 13, 14, and 16 as follows:

User

Change

during

Setting

Factory

Valid Access Levels

User

Constant

Number

Name

during

Opera-

tion

Setting

Range

Unit

Factory

Setting

Open Loop

Vector

Flux Vector

H3-02

Gain for terminal 13

0.0 to

1000.0

%

100.0

B

B

H3-03

Bias for terminal 13

--100.0 to

100.0

%

0.0

B

B

H3-10

Gain for terminal 14

0.0 to

1000.0

%

100.0

A

A

H3-11

Bias for terminal 14

--100.0 to

100.0

%

0.0

A

A

H3-06

Gain for terminal 16*

0.0 to

1000.0

%

100.0

B

B

H3-07

Bias for terminal 16*

--100.0 to

100.0

%

0.0

B

B

*

The settings for terminal 16 are valid only when the multi-function analog input has been se-

lected. The gain and bias set here will be disregarded if a frequency reference is selected and
the values set for terminal 13 will be used.

Frequency
reference

0 V

(

4 mA

)

10 V

(

20 mA

)

Use the current values shown in
parentheses when current input
has been selected.

Max. output frequency

u

Gain

100

Max. output frequency

u

Bias
100

Fig

6.2

Gain and Bias Chart

Analog Input Filter Time Constant: H3-12

D

A primary delay digital filter can be set for all three analog inputs (frequency reference (voltage), fre-
quency reference (current), and multi-function analog input)

User

Change

during

Setting

Factory

Valid Access Levels

User

Constant

Number

Name

during

Opera-

tion

Setting

Range

Unit

Factory

Setting

Open Loop

Vector

Flux Vector

H3-12

Analog input filter time
constant

0.00 to 2.00

s

0.00

A

A

D

This setting is effective when there are sudden changes or noise in the analog input signal.