7.4

Optional Functions

- 69

Figure 7.39 shows the sequence of auto-winding change method.

P1-01 Winding change frequency

Max. Output frequency

Winding change
hysteresis

P1--02

10 V

0 V

Y winding

Y winding

winding

Analog frequency reference

Run Command

Fig

7.39

Auto-winding change sequence

7.4.3 Setting/Adjusting the Winding Change Constants

J

Winding Change Constants: P1-01 to P1-05

Winding change frequency: P1-01

User

Change

during

Setting

Factory

Valid Access Levels

User

Constant

Number

Name

during

Opera-

tion

Setting

Range

Unit

Factory

Setting

Open Loop

Vector

Flux Vector

P1-01

Winding change fre-
quency

0.0 to 400.0

Hz

0.0

A

A

D

Sets winding change frequency when auto-winding change method is used. Set P1-01 lower than the
max. frequency of the Y (low speed) -winding.

Winding change hysteresis: P1-02

User

Change

during

Setting

Factory

Valid Access Levels

User

Constant

Number

Name

during

Opera-

tion

Setting

Range

Unit

Factory

Setting

Open Loop

Vector

Flux Vector

P1-02

Winding change hyster-
esis

0.0 to 20.0

--

5.0

A

A

D

Sets the hysteresis of the winding change frequency.