Yaskawa VS-626 MC5 User Manual

Page 265

Advertising
background image

Specifications

- 4

Table

11.2

400 V Class Inverters

Model number
CIMR-MC5A

40P4

40P7

41P5

42P2

43P7

45P5

47P5

4011

4015

4018

4022

4030

4037

4045

4055

4075

Max. applicable motor
output (kW)

0.4

0.75

1.5

2.2

3.7

5.5

7.5

11

15

18.5

22

30

37

45

55

75

Rated output capac-
ity (kVA)

1.4

2.6

3.7

4.7

6.1

11

14

21

26

31

37

50

61

73

98

130

Ou

Rated output current
(A)

1.8

3.4

4.8

6.2

8

14

18

27

34

41

48

65

80

96

128

165

Ou

Max. output voltage
(V)

3-phase, 380 to 460 VAC (Proportional to input voltage.)

Rated output fre-
quency (Hz)

Up to 400 Hz (available by programming.)

Voltage (V)
Frequency (Hz)

3-phase, 380 to 460 VAC, 50/60 Hz

Po

Allowable voltage
fluctuation

+10%, --15%

Allowable frequency
fluctuation

5%

Control method

Sine wave PWM

Torque characteris-
tics

150% at 1 Hz (150% at 0 r/min with PG).

Speed control range

1: 100 (1: 1000 with PG)*

2

Speed control accu-
racy

0.2% ( 0.02% with PG)*

2

Speed control re-
sponse

5 Hz (30 Hz with PG)*

2

Torque limits

Provided (4 quadrant steps can be changed by constant settings.)

Torque accracy

5%

Frequency control
range

0.1 to 400 Hz

Co Frequency accuracy

(temperature charac-

Digital references:

0.01% (--10 to +40 )

(temperature charac-
teristics)

Analog references: 0.1% (25

10 )

Frequency setting

Digital references: 0.01 Hz

Frequency setting
resolution

Analog references: 0.03 Hz/60 Hz (11 bits + sign)

Output frequency
resolution

0.001 Hz

Overload capacity

150% of rated current for one minute

Frequency setting
signal

--10 to 10 V, 0 to 10 V, 4 to 20 mA

Acceleration/Decel-
eration time

0.01 to 6000.0 s (4 selectable combinations of independent acceleration and deceleration settings)

Braking torque

Approximately 20%

Motor protection

Protection by electronic thermal overload rerlay.

Instantaneous over-
current protection

Stops at approx. 200% of rated output current.

Fuse blown protec-
tions

Stops for fuse burnout.

Overload protection

Stops in one minute at approx. 150% of rated output current.

Overvoltage protec-
tion

Stops when main-circuit DC voltage is approx. 820 V.

Pr

Undervoltage protec-
tion

Stops when main-circuit DC voltage is approx. 380 V.

Momentary power
loss ridethru

Stops for 15 ms or more. By selecting the momentary power loss mode, operation can be continued if power is restored within 2 s.

Cooling fin overheat-
ing

Protection by thermistor.

Stall prevention

Stall prevention during acceleration, deceleration, or running.

Grounding protection

Protection by electronic circuits. (Overcurrent level)

Charge indicator (in-
ternal LED)

Lit when the main circuit DC voltage is approx. 50 V or more.

11