11.1

Standard Inverter Specifications

- 3

Model number
CIMR-MC5A

2075

2055

2045

2037

2030

2022

2018

2015

2011

27P5

25P5

23P7

22P2

21P5

20P7

20P4

Ambient operating
temperature

--10

q to 40qC (Enclosed wall-mounted type)

10

q to 45qC (Open chassis type)

Ambient operating
humidity

90 % RH max.

En Storage temperature

--20 to +60

Application site

Indoor (no corrosive gas, dust, etc.)

Altitude

1000 m max.

Vibration

10 to 20 Hz, 9.8 m/s

2

(1G) max.; 20 to 50 Hz, 2 m/s

2

(0.2G) max

* 1. The maximum applicable motor output is given for a standard 4-pole Yaskawa motor. When selecting the actual motor and

Inverter, be sure that the Inverter’s rated current is applicable for the motor’s rated current.

* 2. Tuning is sometimes required.