Wiring

3.7.5 Selecting the Number of PG (Encoder) Pulses

- 30

3.7.5 Selecting the Number of PG (Encoder) Pulses

J

PG-B2

The maximum response frequency is 32,767 Hz.
Use a PG that outputs a maximum frequency of approximately 20 kHz for the rotational speed of the motor.

Motor speed at maximum frequency output (

r

min

)

60



PG

rating (

p

rev

)

20, 000 Hz

Some examples of PG output frequency (number of pulses) for the maximum frequency output are shown
in Table 3.15.

Table

3.15

PG Pulse Selection Examples

Motor’s Maximum Speed r/min

PG Rating

p/rev

PG Output Frequency for Maximum

Frequency Output Hz

1800

600

18,000

1500

800

20,000

1200

1000

20,000

900

1200

18,000

Note 1.The motor speed at maximum frequency output is expressed as the sync rotation speed.

2. The PG power supply is 12 V.
3. A separate power supply is required if the PG power supply capacity is greater than

200 mA. (If momentary power loss must be handled, use a backup capacitor or other
method.)

PG power supply

Capacitor for power mo-
mentary power loss

Signals

Fig

3.29

PG-B2 Connection Example

J

PG-X2

Both 12V and 15V are available as PG power supply. Verify the PG power supply specifications before
connection.
The maximum response frequency is 300 kHz.
Use the following equation to computer the output frequency of the PG (fPG).

f

PG

(

Hz

)

Motor speed at maximum frequency output (

r

min

)

60



PG

rating (

p

rev

)

A separate power supply is required if the PG power supply capacity is greater than 200 mA. (If momen-
tary power loss must be handled, use a backup capacitor or other method

.)

PG power

0 V 12V

Capacitor for momen-
tary power loss

Fig

3.30

PG-X2 Connection Example