Yaskawa VS-626 MC5 User Manual

Page 111

Advertising
background image

Basic Operation

6.1.3 Frequency Reference from Digital Operator: b1-01, o1-03, d1-01 to d1-09

- 8

J

Preset Frequency Reference Values: d1-01 through d1-09

User

Change

during

Setting

Factory

Valid Access Levels

User

Constant

Number

Name

during

Opera-

tion

Setting

Range

Unit

Factory

Setting

Open Loop

Vector

Flux Vector

d1-01

Frequency reference 1

0 to 400.00

o1-03

0.00 Hz

Q

Q

d1-02

Frequency reference 2

0 to 400.00

o1-03

0.00 Hz

Q

Q

d1-03

Frequency reference 3

0 to 400.00

o1-03

0.00 Hz

Q

Q

d1-04

Frequency reference 4

0 to 400.00

o1-03

0.00 Hz

Q

Q

d1-05

Frequency reference 5

0 to 400.00

o1-03

0.00 Hz

B

B

d1-06

Frequency reference 6

0 to 400.00

o1-03

0.00 Hz

B

B

d1-07

Frequency reference 7

0 to 400.00

o1-03

0.00 Hz

B

B

d1-08

Frequency reference 8

0 to 400.00

o1-03

0.00 Hz

B

B

d1-09

Jog frequency reference

0 to 400.00

o1-03

6.00 Hz

Q

Q

D

The units for these values are set in o1-03.

D

The frequency reference default value and set value will change when o1-03 is changed.
For example, if preset reference 1 is set to 6.00 Hz and o1-03 is changed to 1 (0.01% units), the setting
for preset reference 1 will become 10.00%.

D

When using preset references 2 through 8, be sure to set multi-step speed references 1, 2, and 3 in the
multi-function inputs (H1-01 through H1-06) as required.

D

When using the jog function, set the jog frequency reference in constant d1-09. When jogging from
an external terminal, set the multi-function inputs (H1-01 through H1-06) to “Jog Frequency Refer-
ence,” “Forward Jog,” or “Reverse Jog” as required.

D

The multi-function input setting is unnecessary when jogging from the Operator.

6