Yaskawa VS-626 MC5 User Manual

Page 185

Advertising
background image

7.3

Common Functions

- 47

User

Change

during

Setting

Factory

Valid Access Levels

User

Constant

Number

Name

during

Opera-

tion

Setting

Range

Unit

Factory

Setting

Open Loop

Vector

Flux Vector

H5-01

Station address

0 to 20

--

1F

A

A

Baud Rate: H5-02

D

Set the baud rate for MEMOBUS communications.

User

Change

during

Setting

Factory

Valid Access Levels

User

Constant

Number

Name

during

Opera-

tion

Setting

Range

Unit

Factory

Setting

Open Loop

Vector

Flux Vector

H5-02

Communication speed
selection

0 to 3

--

3

A

A

D

Settings

Setting

Baud Rate

0

1200 bps

1

2400 bps;

2

4800 bps

3

9600 bps

Communication Parity: H5-03

D

Set the parity for MEMOBUS communications.

User

Change

during

Setting

Factory

Valid Access Levels

User

Constant

Number

Name

during

Opera-

tion

Setting

Range

Unit

Factory

Setting

Open Loop

Vector

Flux Vector

H5-03

Communication parity
selection

0 to 2

--

0

A

A

D

Settings

Setting

Function

0

No parity

1

Even parity

2

Odd parity

Stopping Method after Communications Error: H5-04

D

Set the stopping method to used after a communications error is detected.

User

Change

during

Setting

Factory

Valid Access Levels

User

Constant

Number

Name

during

Opera-

tion

Setting

Range

Unit

Factory

Setting

Open Loop

Vector

Flux Vector

H5-04

Stopping method after
communication error

0 to 3

--

3

A

A

D

Settings

Setting

Function

0

Deceleration to stop (deceleration time:C1-02)

1

Coast to stop

2

Emergency stop (deceleration time:C1-09)

3

Continue operation (display only)

Communications Error Detection: H5-05

D

Set whether or not to detect a communications timeout as a communications error.

User

Change

during

Setting

Factory

Valid Access Levels

User

Constant

Number

Name

during

Opera-

tion

Setting

Range

Unit

Factory

Setting

Open Loop

Vector

Flux Vector

H5-05

Communication error
detection selection

0 1

--

1

A

A

D

Settings

Setting

Function

0

Do not detect as communications error.

1

Detect as communications error.

7