3 user constant access levels – Yaskawa VS-626 MC5 User Manual

Page 69

Advertising
background image

Setting User Constants

4.2.3 User Constant Access Levels

- 6

4.2.3 User Constant Access Levels

The VS-626MC5 has three access levels which divide the various user constants based on their applica-
tions, as shown below. The access level restricts which user constants can be set or displayed.

Quick-start

Allows reading/setting of user constants required for simple operation. (factory preset)

Basic

Allows reading/setting of Basic user constants.

Advanced

Allows reading/setting of all user constants.

Set the access level in initialize mode with user constant A1-01.

J

Changing the Access Level from Quick-start to Basic

The Inverter is set at the factory to start in the Quick-start access level. Use the following procedure to
change from the Quick-start level to the Basic level.

Step

Key Sequence

Digital Operator Display

Remarks

1

MENU

MC5

Main Menu

Operation

2

MC5

Main Menu

Initialize

3

DATA

ENTER

Select Language

English

4

Access Level

QUICK--START

5

DATA

ENTER

A1

--

01 = 2

QUICK--START

6

A1

--

01 = 3

Basic

7

DATA

ENTER

Entry Accepted

Access Level

Basic

After approx. 3 seconds, the Operator
display is as shown on the left.

As shown above, Quick-start has changed to Basic.
These seven steps can be illustrated as when in Figure 4.4.

MC5

Main Menu

Operation

MC5

Main Menu

Initialize

Select Language

English

Access Level

QUICK--START

Access Level

Basic

MENU

DAT

A

ENTER

A1

--

01 = 2

QUICK--START

A1

--

01 = 3

Basic

Entry Accepted

DAT

A

ENTER

DAT

A

ENTER

Fig

4.4

Changing Quick-start to Basic

4