12.5

User Constants

- 19

Table 12.1

User Constants (Continued)

No.

Name

(Display)

Factory

Setting

Setting

No.

Name

(Display)

Factory

Setting

Setting

P1--01

Winding Change frequency

(Changeover Freq)

0.0

P3--05

Positioning Completion Detection Width
(ORE Set Pulse)

5

pulses

P1--02

Winding change hysteresis
(Frequency Width)

0.5

P3--06

Positioning Completion Cancel Width
(ORE Reset Pulse)

10

pulses

P1--03

MC Answerback error detection
(Ansback Det Time)

0.20

P3--07

Orientation Speed
(ORT Speed)

400

r/min

P1--04

Motor Constant selection
(Wye Winding Sel)

1

P3--08

Gear Ratio (H)
(Gear Ratio H)

1.0000

P1--05

Programming mode valid/invalid during run
(Program Mode @ RUN)

1

P3--11

Gear Direction
(Gear Direction)

0

P3--01

Main Axis Zero Point
(Position Origin)

0

pulses

P3--12

Dither Level
(Dither Level)

0

P3--02

Position Control Gain (H)
(Position Gain H)

10

12