1 open-loop vector control – Yaskawa VS-626 MC5 User Manual

Page 140

Advertising
background image

Advanced Operation

- 2

7.1

Open-loop Vector Control

The functions that can be used with open-loop vector control are listed in Table 7.1. Details on functions that
are specific to open-loop vector control (i.e. those marked with a ) are provided in the following table.

Table

7.1

Open-loop Vector Control Functions

Group

Function

Comments

Control

Method

Group

Function

Comments

Open

Loop

Vector

Flux

Vector

b1

Sequence

Settings such as the reference input method

b

Application

b2

DC Injection Braking

DC injection braking function settings

b

Application

b3

Speed Search

Speed search function settings

b8

Energy Saving

Not used. (Can’t be set.)

C1

Accel/Decel

Acceleration/deceleration time settings

C2

S-Curve Acc/Dec

S-curve characteristics for acceleration/deceleration times

C3

Motor-Slip Compensation

Slip compensation function settings

C Tuning

C4

Torque Compensation

Torque compensation function settings

C Tuning

C5

Speed Controls

Not used. (Can’t be set.)

C6

Carrier Frequency

Carrier frequency settings

C8

Factory Tuning

Adjustment for open-loop vector control

d1

Preset Reference

Frequency reference settings (when using Operator)

d2

Reference Limits

Frequency upper and lower limit settings

d

Reference

d3

Jump Frequencies

Prohibited frequency settings

d4

Reference Frequency Hold
Function

Up/Down, Accel/Decel stop hold frequency setting

E1

V/f Pattern

Motor constant settings

E2

Motor Setup

Motor constant settings

(Motor constants are set by the autotuning function.)

E

Motor

E3

Motor 2 Control Methods

Control method settings for motor 2.

E

Motor

E4

Motor 2 V/f Characteristics

V/f characteristics settings for motor 2.

E5

Motor 2 Motor Constants

Motor constant settings for motor 2.

F1

PG speed control card set-
tings

User constant settings for a PG Card

F2

Analog Reference Card AI

User constant settings for an Analog Reference Card

F3

Digital Reference Card DI

User constant settings for a Digital Reference Card

F4

Analog Monitor Card AO

User constant settings for an Analog Monitor Card

F

Options

F5

Digital Output Card DO

User constant settings for a Digital Output Card

F

Options

F6

Digital Output Card DO

User constant settings for a Digital Output Card

F7

Pulse Monitor Card PO

User constant settings for a Pulse Monitor Card

F8

SI-F/SI-G Transmission
Card

User constant settings for a Transmission Card

F9

CP-916B Transmission
Card

User constant settings for a Transmission Card

H1

Multi-function Inputs

Function selection for multi-function inputs

H2

Multi-function Outputs

Function selection for multi-function outputs

H T

i

l

H3

Analog Inputs

Function selection for analog inputs

H Terminal

H4

Multi-function Analog Out-
puts

Function selection for analog outputs

H5

MEMOBUS Communica-
tions

MEMOBUS communications settings

L1

Motor Protection Functions

Sets thermal functions that protect the motor.

L2

Power Loss Ridethru

Selects the power-loss processing method.

L3

Stall Prevention

Accel/Decel stall prevention settings and selection

L

Protection

L4

Reference Detection

Frequency detection settings and selection

L

Protection

L5

Fault Restart

Fault restart function settings

L6

Torque Detection

Sets overtorque detection functions 1 and 2 (by torque)

L7

Torque Limit

Four-quadrant individual torque limit settings

L8

Hardware Protection

Hardware overheating and open-phase protection settings

o

Operator

o1

Monitor Select

Selects the Operator’s display and setting methods.

o

Operator

o2

Key Selections

Operator’s key function selection and other constants

7