7.3.4 Option Constants: F

- 26

D

If the trim control increase command is ON when a frequency reference is input on the analog input,
the trim control level will be added to the analog frequency reference and then output as the output
frequency. If the trim control decrease command is ON, the frequency reference will be decreased by
the trim control level.

User

Change

during

Setting

Factory

Valid Access Levels

User

Constant

Number

Name

during

Opera-

tion

Setting

Range

Unit

Factory

Setting

Open Loop

Vector

Flux Vector

d4-02

+-- Speed limits

0 to 100

%

25

A

A

D

Set the trim control level as a percentage of the maximum output frequency.

D

If the frequency reference minus the trim control level is less than zero, the output frequency will be
zero.

D

Refer to the description of Multi--function Inputs (H1) for details on the trim control increase and trim
control decrease commands.

7.3.4 Option Constants: F

J

Installing Option Cards

A maximum of three Option Cards can be installed in the Inverter. The installation location of each is deter-
mined by the type of Card. Be sure to install the Cards in their correct locations.
Constants of the Option Cards can be referred or set with the access level Basic.

Table

7.4

Option Card Specifications

Type of card

Model

Specifications

Location

Analog Reference Card

AI-14U

14-bit analog, 2 inputs (voltage/current)

C

Analog Reference Card

AI-14B

14-bits analog, 3 inputs

C

Digital Reference Card

DI-08

8-bit digital input (BCD/binary)

C

Digital Reference Card

DI-16H2

16-bit digital input (BCD/binary)

C

PG Speed Control Card

PG-B2

Complementary, A/B-phase input

A

PG Speed Control Card

PG-X2

Line-driver, A/B-phase input

A

Analog Monitor Card

AO-08

8-bit analog output, 2 channels

D

Analog Monitor Card

AO-12

12-bit analog output, 2 channels

D

Pulse Monitor Card

PO-36F

Pulse frequency output

D

Installation Procedure

1. Turn OFF the Inverter’s main-circuit power supply. Wait at least one minute (or at least three minutes

for models of 30 kW or more).

2. Remove the Inverter’s front cover. Check to be sure that the CHARGE LED is turned OFF.
3. Check the Option Card’s installation location (A, C, or D). (See Figure 7.15.)
4. Insert the accessory spacer into the spacer mounting hole in the Inverter mounting base.
5. Align the Option Card connector with the connector position on the control board, and then pass the

spacer to the spacer mounting hole on the card.
Press firmly until the spacer snaps into place.

6. Connect the Option Card’s FG connection line to the Inverter ground terminal (terminal 12).