Yaskawa VS-626 MC5 User Manual

Page 71

Advertising
background image

Setting User Constants

4.2.3 User Constant Access Levels

- 8

Setting a User Constant in the Quick-start Access Level

The user constant level will be displayed when the DATA/ENTER Key is pressed at the programming
mode display.
Use the following display to set the acceleration time to 20.0 s.

Step

Key Sequence

Digital Operator Display

Remarks

1

MENU

MC5

Main Menu

Operation

2

Press twice.

MC5

Main Menu

Programming

3

DATA

ENTER

Reference source

Terminals

Changed to constant setting level.

4

Run Source

Terminals

5

Stopping Method

Ramp to Stop

6

Accel Time 1

C1

--

01 = 10

.

0 Sec

7

DATA

ENTER

Accel Time 1

0010

.

0 Sec

Selects the user constant so that the
leading 0 blinks. The digit that is
blinking can be changed.

8

RESET

Press twice.

Accel Time 1

0010

.

0 Sec

Blinking digit moves 2 places to the
right.

9

Accel Time 1

0020

.

0 Sec

Changes 1 to 2.

10

DATA

ENTER

Entry Accepted

Accel Time 1

C1

--

01 = 20

.

0 Sec

After approx. 3 seconds, the Operator
display is as shown on the left.

The acceleration time has been set to 20.0 seconds.

Step

Key Sequence

Digital Operator Display

Remarks

11

ESC

MC5

Main Menu

Programming

Returns to programming mode display.

4

A

EXAMPLE

"

Advertising