User Constants

8.2.3 Reference Constants: d

- 12

J

Reference Limits: d2

Constant

Name

Setting

Factory

Change

during

Control Methods

Constant

Number

Display

Description

Setting

Range

Factory

Setting

g

during

Opera-

tion

Open Loop

Vector

Flux Vector

Page

d2-01

Frequency reference
upper limit

Sets the output frequency upper
limit as a percentage of the maxi-

0.0 to
110 0

100.0

B

B

- 24

d2 01

Ref Upper Limit

limit as a percentage of the maxi
mum output frequency.

110.0

100.0

B

B

- 24

d2-02

Frequency reference
lower limit

Sets the output frequency lower
limit as a percentage of the maxi-

0.0 to
109 0

0.0

B

B

- 24

d2 02

Ref Lower Limit

limit as a percentage of the maxi
mum output frequency.

109.0

0.0

B

B

- 24

J

Jump Frequencies: d3

Constant

Name

Setting

Factory

Change

during

Control Methods

Constant

Number

Display

Description

Setting

Range

Factory

Setting

g

during

Opera-

tion

Open Loop

Vector

Flux Vector

Page

d3-01

Jump frequency 1

Set the center values of the jump
frequencies in Hz.

0 0

B

B

25

d3-01

Jump Freq 1

frequencies in Hz.

This function is disabled by set-

ting the jump frequency to 0 Hz

0.0

B

B

- 25

d3-02

Jump frequency 2

ting the jump frequency to 0 Hz.
Always ensure that the following
applies:

0.0 to

0 0

B

B

25

d3-02

Jump Freq 2

applies:
d3-01

 d3-02  d3-03

Operation in the jump frequency

0.0 to
400.0

0.0

B

B

- 25

d3-03

Jump frequency 3

Operation in the jump frequency
range is prohibited but during ac-
celeration and deceleration,

d h

hl

i h

0 0

B

B

25

d3-03

Jump Freq 3

celeration and deceleration,
speed changes smoothly without
jump.

0.0

B

B

- 25

d3-04

Jump frequency width

Sets the jump frequency bandwidth
in Hz.

0.0 to

1 0

B

B

25

d3-04

Jump Bandwidth

in Hz.

The jump frequency will be the

jump frequency

r d3-04.

0.0 to

20.0

1.0

B

B

- 25

J

Reference Frequency Hold: d4

Constant

Name

Setting

Factory

Change

during

Control Methods

Constant

Number

Display

Description

Setting

Range

Factory

Setting

g

during

Opera-

tion

Open Loop

Vector

Flux Vector

Page

d4-01

Frequency reference
hold function selec-
tion

Sets whether or nor frequencies on
hold will be recorded.
0: Disabled (when operation is

stopped or the power is turned
on again starts at 0.)

1: Enabled (when operation is

stopped or the power is turned
on again starts at the previous

0 1

0

A

A

- 25

MOP Ref Memory

pp

p

on again starts at the previous
hold frequency.)

This function is available when

the multi--function inputs “accel/
decel Ramp Hold” or “up/down”
commands are set.

d4-02

+ -- Speed limits

Sets the increase/decrease frequen-
cy for analog frequency references
as a percentage of the maximum
output frequency.

0 to 100

25

A

A

26

d4-02

Trim Control Lvl

output frequency.

This function is available when

the multi--function inputs “Trim
Clt Increase” or “Trim Clt De-
crease” is set.

0 to 100

25

A

A

- 26

8