12.5

User Constants

- 15

12.5 User Constants

Factory settings are given for a 200 V class Inverter of 0.4 kW set to open loop vector control (A1-02 = 2).

Table

12.1

User Constants

No.

Name

(Display)

Factory

Setting

Setting

No.

Name

(Display)

Factory

Setting

Setting

A1-00

Language selection for digital operator display
(Select Language)

1

1

b5--08

-- --

4

0.00

A1-01

Constant access level
(Access Level)

2

b6-01

-- --

4

0.0

A1-02

Control method selection
(Control Method)

2

1

b6-02

-- --

4

0.0

A1-03

Initialize
(Init Parameters)

0

b6-03

-- --

4

0.0

A1-04

Password 1
(Enter Password)

0

b6-04

-- --

4

0.0

A1-05

Password 2
(Select Password)

0

b7-01

-- --

4

0.0

A2-01

to

A2-32

User setting constant
(User Pram 1 to 32)

b7-02

----

4

0.05

b1-01

Reference selection
(Reference Source)

1

C1-01

Acceleration time 1
(Accel Time 1)

10.0

b1-02

Operation method selection
(Run Source)

1

C1-02

Deceleration time 1
(Decel Time 1)

10.0

b1-03

Stopping method selection
(Stopping Method)

0

C1-03

Acceleration time 2
(Accel Time 2)

10.0

b1-04

Prohibition of reverse operation
(Reverse Oper)

0

C1-04

Deceleration time 2
(Decel Time 2)

10.0

b1-05

Operation selection for setting of E1-09 or less
(Zero-Speed Oper)

0

C1-05

Deceleration time 2
(Decel Time 2)

10.0

b1-06

Read sequence input twice
(Cntl Input Scans)

1

C1-06

Acceleration time 3
(Accel Time 3)

10.0

b1-07

Operation after switching to remote mode

*2

(LOC/REM RUN Sel)

0

C1-07

Acceleration time 4
(Accel Time 4)

10.0

b1-08

Run command selection for PRG mode (RUN
CMD at PRG)

0

C1-08 Deceleration time 4

(Decel Time 4)

10.0

b2-01

Zero speed level (DC injection braking start
frequency)
(DCInj Start Rreq)

0.5

C1-09

Emergency stop time
(Fast Stop Time)

10.0

b2-02

DC injection braking current
(DCinj Current)

50

C1-10

Accel/decel time setting unit
(Acc/Dec Units)

1

b2-03

DC injection braking time at start
(DCInj Time @ Start)

0.00

C1-11

Accel/decel time switching frequency
(Acc/Dec SW Freq)

0.0

b2-04

DC injection braking time at stop
(DCInj Time @ Stop)

0.50

C2-01

S-curve characteristic time at acceleration start
(SCrv Acc @ Start)

0.20

b3-01

Speed search selection at start
(SpdSrch at Start)

0

3

C2-02

S-curve characteristic time at acceleration end
(SCrv Acc @ End)

0.20

b3-02

Speed search operating current
(SpdSrch Current)

100

3

C2-03

S-curve characteristic time at deceleration start
(SCrv Dec @ Srat)

0.20

b3-03

Speed search deceleration time
(SpdSrch Dec Time)

2.0

C2-04

S-curve characteristic time at deceleration end
(SCrv Dec @ End)

0.00

b4-01

Timer function ON-delay time
(Delay-ON Timer)

0.0

C3-01

Slip compensation gain
(Slip Comp Gain)

1.0

3

b4-02

Timer function OFF-delay time
(Delay-OFF Timer)

0.0

C3-02

Slip compensation primary delay time
(Slip Comp Time)

200

3

b5-01

-- --

4

0

C3-03

Slip compensation limit
(Slip Comp Limit)

200

b5-02

-- --

4

1.00

C3-04

Slip compensation during regeneration
(Slip Comp Regen)

0V

b5-03

-- --

4

1.0

C3-05

Flux calculation method
(Flux Select)

0

b5-04

-- --

4

100.0

C3--06

Output voltage limited operation selection
(Output V Limit)

0

b5-05

-- --

4

0.00

C4-01

Torque compensation gain
(Torq Comp Gain)

1.00

b5-06

-- --

4

100.0

C4-02

Torque compensation time constant
(Torq Comp Time)

20

3

b5-07

-- --

4

0.0

C4--03

Start torque compemsation (forward direction)
(F TorqCmp @ Start)

0.0

* 1. Not initialized. (Japanese standard specifications: A1-01 = 1, A1-02 = 2)
* 2. Not displayed for some models depending on software version No.
* 3. Factory setting depends on the control method (A1-02).
* 4. Constants that cannot be used. (Do not change the settings)